"Revolver" rotary device control system
Tilda Publishing
The control system based on the Siemens S7-1200 controller and Weintek cMT2078x HMI regulates the speed of the revolver disc and vibrators via the Siemens Sinamics V20 frequency converter. Automatic and manual operating modes, product recipe selection, replaceable and continuous production counters, data archiving on USB with the possibility of collection via FTP, and data transfer via OPC UA are implemented. Error display with diagnostics.

prescription selection of products based on SAP codes;

replaceable and through-type production counters;

archiving data on a USB drive with the ability to retrieve it via FTP without removing the drive;



automatic and manual modes of operation of units;

control of the rotation speed of the “revolver” disc and vibrators via Siemens Sinamics V20 frequency converter;

Implements:
Work has been completed on dismantling old equipment, installing a new control panel, distribution panels and boxes, and laying cables and cable routes.
Разработана и внедрена новая автоматизированная система управления на базе контроллера Siemens S7-1200 с HMI-панелью Weintek cMT2078x.
display and diagnosis of errors with indication of causes and sources.
data transfer via OPC UA protocol;
A new automated control system based on a Siemens S7-1200 controller with a Weintek cMT2078x HMI panel has been developed and implemented.
After modernization
Before modernization
prescription selection of products based on SAP codes;

replaceable and through-type production counters;
archiving data on a USB drive with the ability to retrieve it via FTP without removing the drive;



automatic and manual modes of operation of units;
control of the rotation speed of the “revolver” disc and vibrators via Siemens Sinamics V20 frequency converter;

Implemented:
Work has been completed on dismantling old equipment, installing a new control panel, distribution panels and boxes, and laying cables and cable routes.
display and diagnosis of errors with indication of causes and sources.
data transfer via OPC UA protocol;
A new automated control system based on a Siemens S7-1200 controller with a Weintek cMT2078x HMI panel has been developed and implemented.
Projects
Contact us — call us, send us an email, or fill out the feedback form
Still have questions?
Contact us — call us, send us an email, or fill out the feedback form
Still have questions?
By clicking the button, you consent to the processing of your personal data and agree to the privacy policy.
Menu
Contacts
+7 999 529 30 50
mvsk.org
Menu
Contacts
+7 999 529 30 50
mvsk.org